3.9.2
”Check“ machine condition prior to activation
Before turning on the Vacuum filling machine it must be established that:
-
Sliding drum, valve and sliding plate are readily available and properly
arranged.
-
All parts, particularly the feeder and stopper must be properly mounted
and the top plate is closed.
-
Movable parts are not damaged or jammed up.
-
Electric components such as switches, cords, plugs push buttons etc
are intact and functional.
-
The product to be processed corresponds with the agreed upon usage
(see chapter 2.2.1 Operation area and agreed upon usage)
Defects or worn parts interfere with safety and must be replaced immedi-
ately!
According to
UVV meat cutting machines (VBG 19) policy holders
must inspect the functioning ability of protective equipment on every
work day before the "start up" of meat grinding machines. All estab-
lished faultiness must immediately be reported by the responsible
personnel. In the case of a defect which could jeopardize the work
safety, then the Vacuum filling machine cannot be put into operation.
The supervising person must immediately replace or repair defective
protective equipment.