RVF 327, 327 S, 330, 330 S
ex no. 1200
Maintenance
Version 1.5
page 127 of 144
-
Check all safety switches (Magnetic switches upper part, safety switch
for the folding hopper steps) on the function. If there should be a shortage
established, then the Vacuum filling machine is to be shut down immedi-
ately and cannot be put back into service before the shortage is repaired.
-
Condition of the electric cable, the plug, and the socket must be visually
inspected for damages.
5.4.2
Weekly maintenance (every 40 working hours)
Generally Vacuum filling machine has intended greasing fittings (Figure 55, page
129). These are colored and marked and can be found immediately through
pointers. These cases apply:
greasing according to separate3 greasing instructions. Pre- grease fitting (grease
fitting) ca. 3,0 cm³ brings in fat.. Attention! Only moist edible fat on a synthetic
basis can be used according to USDA H1, such as e.g. Paraliq GA343. other
than fats are not allowed acc. to USDA H1, , because
-
These are not permitted for use in food processing in the Vacuum fill-
ing machine.
-
By mixing with other types of fat, the danger of "soaping" exists, and
therefore is a potential breakdown in the smearing process.
With damages through non-compliance with this instruction there is no responsi-
bility through the machine manufacturer or their corporation!
5.4.3
6 Month maintenance
(Every 1.000 operational hours, equivalent of 6 Months at 8h/day, but at VERY least once
yearly)
Maintenance can only be carried out through REX-technicians or through trained technicians
of our authorized appointed dealers. The work carried out by the maintenance is listed in the
service mask of our touch-control. The controls hints in intervals to the service work to be
carried out. (Figure 37, page 85)
For the maintenance of possible guarantee claims is a pre-requisite that all services have
been carried out and can be proven through filled out upkeep listed maintenance and these
are saved in the touch screen controls..