R01UH0092EJ0110 Rev.1.10
Page 591 of 807
Jul 31, 2012
M16C/64C Group
26. Consumer Electronics Control (CEC) Function
CFALL1-CFALL0 (Falling timing select bit) (b5-b4)
The falling timing of the signal in transmission is specified. Do not write to bits CFALL1 to CFALL0 while
transmitting/receiving.
CREGFLG (Receive edge detect flag) (b6)
See Figure 26.2 “Operation of Bits CREGFLG and CREGCLR”.
Condition to become 0:
•
Set the CREGCLR bit in the CECC3 register to 1.
Condition to become 1:
•
Detect a low level input to CEC while the CREGCLR bit is 0.
CABTWEN (Error low pulse output wait control bit) (b7)
This bit is enabled when the CABTEN bit is 1 (low pulse output enabled in reception error).
If a receive error occurs when the CABTWEN bit is set to 1 (low pulse output at rising edge of the CEC
signal) and the CEC input is low, a 3.6 ms low-level pulse is output from the rising edge of the CEC
signal after the error. If there is no rising edge of the CEC signal within 3.6 ms from the reception error,
a low-level pulse is not output because it is assumed that another device output an error low-level
pulse.
Do not write to the CABTWEN bit while transmitting/receiving.
Table 26.7
Falling Timing of Signal in Transmission
Bits CFALL1 to CFALL0
Falling Timing
Start bit
Data bit
00b
Standard value
Standard value
01b
Standard value - 40
μ
s
Standard value - 190
μ
s
10b
Standard value - 100
μ
s
Standard value - 250
μ
s
11b
Standard value - 160
μ
s
Standard value - 310
μ
s