eng eng
Explanation of symbols
Read the operating instructions
before
use
Power tool complies with protection class II
Environmentally friendly disposal
CE conformity mark
1. Technical Data
The REMS CamScope and REMS CamScope S endoscope camera is used for the inspection and damage analysis of locations with difficult access such as cavities,
shafts, pipes etc. and serves for documenting the inspection results in the form of photos and videos, in the REMS CamScope S in the form of videos with voice
recording. The camera cable sets of REMS CamScope and REMS CamScope S are protected against temporary immersion in water (≤ 30 min, ≤ 0.1 bar).
1.1. Supply Format
Set 16-1
Set 9-1
Set 4.5-1
REMS CamScope
175110
175111
175112
* Supply format
* Supply format
* Supply format
Camera cable set Color 16-1
Camera cable set Color 9-1
Camera cable set Color 4.5-1
Add-on mirror, add-on hook
Add-on mirror, add-on hook
Add-on magnet
Add-on magnet
REMS CamScope S
175130
175131
175132
* Supply format
* Supply format
* Supply format
Camera cable set Color 16-1
Camera cable set Color 9-1
Camera cable set Color 4.5-1
Add-on mirror, add-on hook
Add-on mirror, add-on hook
Add-on magnet
Add-on magnet
* Supply format:
Handheld unit, 4 batteries 1.5V, AA, LR6, controller unit, MicroSD-card 2 GB, power supply/charger unit, USB-cable, video cable, case
1.2. Accessories
Camera cable set Color 16-1
175103
Camera cable set Color 9-1
175104
Camera cable set Color 4.5-1
175102
900 mm push cable extension
175105
1.3. Handheld Unit
REMS CamScope
REMS CamScope S
Transmission frequency
2,468 MHz
2,468 MHz
Modulation type
FM
FM
Bandwidth
18 MHz
18 MHz
Radio transmission range
up to 10 m
up to 10 m
Power supply
4 batteries 1.5 V, AA, LR6
4 batteries 1.5 V, AA, LR6
Dimensions
190 × 140 × 40 mm
190 × 165 × 53 mm
Weight
260 g
320 g
1.4. Controller Unit
REMS CamScope
REMS CamScope S
Display
3.5” Color TFT-LCD
3.5” Color TFT-LCD
Pixels (display)
320 × 240
320 × 240
Pixels (recording)
640 × 480
640 × 480
Video system
PAL / NTSC
PAL / NTSC
Reception frequencies
2414, 2432, 2450, 2468 MHz
2414, 2432, 2450, 2468 MHz
Transmission channel
4
not adjustable
Rechargeable batteries
integrated Li-Ion battery 3.7 V, 1.2 Ah integrated Li-Ion battery 3.7 V, 1.2 Ah
Power supply / charger unit
100 – 240 V AC, 50 – 60 Hz, Input /
100 – 240 V AC, 50 – 60 Hz, Input /
5 V DC, 1 A, Output
DC 5 V / 1 A, Output
Video level
0.9 – 1.3 Vpp on 75 Ohm
0.9 – 1.3 Vpp on 75 Ohm
Video rate
27 MB per minute
27 MB per minute
Frame rate
up to 30 frames per second
up to 30 frames per second
Zoom
–
1.5 / 2.0 / 3.0 ×
Dimensions
100 × 70 × 25 mm
105 × 90 × 42 mm
Weight
130 g
240 g
Temperature range
–10°C ... +50°C / +14°F ... +122°F
–10°C ... +50°C / +14°F – +122°F
Humidity
15 – 85% RH
15 – 85% RH
1.5. Camera Cable Set Color
16 mm camera
9 mm camera
4.5 mm camera
Image
sensor
CMOS CMOS CMOS
Number of pixels
704 × 576
640 × 480
320 × 240
Viewing
angle
50° 36° 63°
Focus range
60 – 350 mm
20 – 100 mm
10 – 50 mm
Min. lighting
0 lux
0 lux
0 lux
Power supply
by handheld unit
by handheld unit
by handheld unit
Dimensions
Ø 16 × 970 mm
Ø 9 × 970 mm
Ø 4.5 × 1030 mm
Weight
280 g
190 g
30 g
Video
format
PAL PAL NTSC
Type of protection camera
IP 67
IP 67
IP 67
2. Start-up
Remove the screw from the battery compartment (17) of the handheld unit (5)
(only in REMS CamScope), push the cover in the direction of the arrow to
remove, remove the battery holder, insert 4 1.5 V, AA, LR6 batteries into the
battery holder, pay attention to the position of the plus-minus poles. Push the
battery holder back into the battery compartment, slide in the cover, screw in
the screw (only in REMS CamScope). Always change all four batteries at once.
The controller unit has an integrated Li-Ion battery.
Caution: Mains voltage
present!
Charge the controller battery before start-up. To do so, connect the
supply voltage/Li-Ion charger to the charger/mains socket (16) of the controller
unit and a suitable wall socket. The battery charging time is approximately 3
hours. A full charge lasts for about 2 hours of operation depending on the use.
The controller unit can also be operated with the connected supply voltage/
charger.
Push the controller unit (7) onto the handheld unit (5) from above until it snaps
into place. When inserting the camera cable set (2), make sure that the pin on
the cable plug (3) is pushed into the slit in the cable socket on the handheld
unit (5). Tighten the knurled nut.
The controller unit can be operated both by radio signal and directly with the
handheld unit. If the controller unit (7) is fixed to the handheld unit (5), the signal
transmission takes place via the contact pins on the controller unit and on the
handheld unit. Transmission switches over to radio signal transmission as soon
as the controller unit is removed from the handheld unit. For radio-controlled
operation, make sure that the controller of the REMS CamScope is set to channel
CH 4. This is indicated in the top left hand corner of the display. If this setting
should deviate, it can be corrected to CH 4 by pressing the Down button (12)
several times. No channel must be set manually in the REMS CamScope S.
WMV-Dresden, Ersatzteilservice für Elektrowerkzeuge, Motor- und Gartengeräte