Inline Power Vent Vertical or Horizontal Installation Instructions
Vertical Inline Power Vent Terminations
Rigid Pipe
The minimum components required when using inline power
flue
are:
1 High Wind Cap
1 Rigid Pipe Adaptor
1 Ceiling Firestop
1 Flashing
1 Storm Collar
1 Lengths of pipe to suit wall thickness & vent run
(see chart)
1
Inline Pow
er Flue
Kit
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must
be used to secure rigid pipe to
adaptor.
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in table below or local codes. Note that for
steep roof pitches, the vertical height must be increased. A poor
draft, or down drafting can result from high wind conditions near
big trees or adjoining roof lines, in these cases, increasing the
vent height may solve the problem.
Roof Pitch
Minimum Vent Height
Feet
Meters
flat to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14/12
5
1.52
over 14/12 to 16/12
6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 20/12 to 21/12
8
2.44
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent, American
Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
, ICC Excel,
Olympia Ventis DV,
Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
High Wind Cap
Storm Collar
Ceiling Firestop
Flashing
(not supplied)
Inline Power
Flue
Kit
Lengths of Pipe
Lengths of Pipe
Slip Section
Rigid Pipe Adaptor
VERTICAL INLINE POWER FLUE TERMINATIONS
RIGID PIPE
Roof Pitch
Minimum Flue Height
Meters
flat to 30.26
o
0.61
over 30.26
o
to 33.69
o
0.61
over 33.69
o
to 36.37
o
0.61
over 36.37
o
to 39.81
o
0.76
over 39.81
o
to 42.51
o
0.99
over 42.51
o
to 45.00
o
1.22
over 45.00
o
to 49.40
o
1.52
over 49.40
o
to 53.13
o
1.83
over 53.13
o
to 56.31
o
2.13
over 56.31
o
to 59.04
o
2.29
over 59.04
o
to 60.26
o
2.44
installation