VALVE TRAY REPLACEMENT
PRIOR TO VALVE TRAY REPLACEMENT, ENSURE UNIT
HAS COOLED TO ROOM TEMPERATURE, ALL POWER IS
DISCONNECTED AND GAS SUPPLY IS TURNED OFF.
6. Remove burner by removing 14 screws in locations shown below.
7. Lift out valve tray.
8
.
Replace valve tray and reverse steps.
Diagram 4 - Valve Tray Screw Locations
Diagram 5 - Valve Tray Removal
1. Remove faceplate, inner frame, glass door, front trim piece and inner
panels - see instructions in this manual.
2. Remove logs.
3. Remove burner side panels by lifting out as shown in Diagram 1.
4. Remove burner by removing 2 screws in locations shown below.
Diagram 3 - Log Tray screws
Diagram 1 - Burner Side Panels
Diagram 2 - Burner Screw Locations
5. Remove rear log tray by removing 3 screws as shown in Diagram 3
below.