52
Regency GF950L-2 Gas Fireplace
GAS POWER FLUE INSTALLATION - FRAMING
INLINE POWER FLUE TERMINATIONS
920-210
02.20.20
8
CV72EPV / CB72EPV
Inline Power Vent Vertical or Hortizontal Installation Instructions
• The inline power
flue
can be mounted directly onto a wall, ceiling, stud or truss. Additional supports can be built to support the power
flue
if
needed.
• The inline power
flue
can be oriented in any way if the access panel is accessible.
NOTE: The inline power
flue
will have a directional arrow which must be pointed away from the appliance.
Diagram 1: Inline
power
flue
oriented
vertically
Diagram 2: Inline power
flue
oriented horizontally
Pressure switch orientation if inline
power
flue
is oriented vertically (see
Diagram 1)
Pressure switch orientation if inline power
flue
is oriented horizontally (see Diagram 2)
IMPORTANT: The pressure switch must be oriented as shown
below:
Gas Power
Flue
Installation
-
Framing
Inline Power
Flue
Terminations
Termination
End
Directional
Arrows
Termination
End
Appliance
End
Appliance
End
NOTE: If the power vent is terminated vertically, no action
is required for the pressure switch. If in a horizontal
position, the pressure switch will need to be rotated. See
instructions on next page.
Flue
at appliance end
Flue
at appliance
end
254mm
406mm
installation