Regency GF950L-2 Gas Fireplace
35
maintenance
VERTICAL TERMINATIONS (NON POWER FLUE)
RIGID PIPE 102MM X 168MM
The minimum components required for a basic vertical
termination using Simpson Duravent Rigid Flue System are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor (510-994)
1 Flashing
1 Storm Collar
1 Length of pipe to suit height requirement
(see chart)
When using Rigid Flue other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the flue cap meets the minimum height
requirements specified in local codes. Note that for steep roof
pitches, the vertical height must be increased. A poor draft, or
down drafting can result from high wind conditions near big trees
or adjoining roof lines, in these cases, increasing the flue height
may solve the problem.
Pipe Length
Flashing
Rigid Pipe Adaptor
High wind cap
(not supplied)
(Dura Vent Only)
Roof Pitch
Minimum Flue Height
Meters
flat to 30.26
o
0.61
over 30.26
o
to 33.69
o
0.61
over 33.69
o
to 36.37
o
0.61
over 36.37
o
to 39.81
o
0.76
over 39.81
o
to 42.51
o
0.99
over 42.51
o
to 45.00
o
1.22
over 45.00
o
to 49.40
o
1.52
over 49.40
o
to 53.13
o
1.83
over 53.13
o
to 56.31
o
2.13
over 56.31
o
to 59.04
o
2.29
over 59.04
o
to 60.26
o
2.44