User's Instructionsl

SECTION ONE

Consumer Protection Information

As manufacturers and suppliers of heating products, we take every care, as far as is reasonably
practicable, that these products are so designed and constructed as to meet the general safety
requirement when properly used and installed. To this end, our products are thoroughly tested
and examined before despatch.

IMPORTANT NOTICE: Any alteration that is not approved by the appliance manufacturer
could invalidate the approval of the appliance, operation of the warranty and could affect your
statutory rights.

Health and Safety Notice

Important
This appliance could contain some of the materials, indicated below, that could be interpreted
as being injurious to health and safety. It is the users / installers responsibility to ensure that the
necessary personal protective clothing is worn when handling these materials, see below for
information.

Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yam -

may be harmful

if

inhaled, may be irritating to skin, eyes, nose and throat.

When handling

avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and

eye protection. After handling wash hands and other exposed parts. If a vacuum is used for cleaning the
coals or cleaning after servicing / installation it is recommended that it be of the type fitted with a HEP A

filter.

Disposal of refractory/ceramic materials.

To keep dust to a minimum

these materials should

be securely wrapped in polythene and be clearly labelled 'RCF waste'

.

These materials are not classified as

'hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste.

The PARAGON TURBO PLUS LPG is a fan flued decorative fuel-effect gas fire, which does

not require a chimney but must be installed on a suitable outside wall

.

It is important that the fan outlet, protected by the terminal guard, is kept clear at all

times.

The PARAGON

TURBO

PLUS LPG is designed

and tested to the requirements

of the

European Standard EN 509.

The appliance

is for use on Propane Gas only and requires a 220-240V

50Hz electrical

supply protected by 3A fuse. It should only be installed by a competent person Le. CORGI-

registered,

in

accordance

with

the

GAS

SAFETY

(INSTALLATION

AND

USE)

REGULATIONS

and I

.

E

.

E

.

WIRING REGULATIONS.

Like all appliances

incorporating

an aerated

burner

with a fanned

flue system

a low

frequency noise may be heard.

It is advised that the PARAGON TURBO PLUS LPG fanned flued fire is serviced annually as
it is more likely to provide trouble-free operation.

The flue be regularly checked and kept clear of any obstruction.

579

22

Summary of Contents for TURBO PLUS LPG

Page 1: ...osed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEP A filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of ...

Page 2: ... removable ashtray cover lower section The ash tray cover must have cut outs and or holes which provide ventilation to the underside of the burner The effective area of ventilation through the ash tray cover must be greater than 1365mm2 2 12 sq ins TYPICAL FIRE FRONT e ASH TRAY COVER ELECTRICAL CONNECTION WARNING THIS APPLIANCE MUST BE EARTHED The wiring in the mains lead on this appliance is colo...

Page 3: ...the form of an Oxygen Depletion System which constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level reduces THIS DEVICE MUST NOT BE OVERRIDDEN If this occurs do not attempt to relight the appliance until a qualified engineer has checked it the problem may not be due to lack of air or a defective flue When the appliance is not in use the gas control and...

Page 4: ...d Note that the knob latches in position at either end of this movement and must be pushed in slightly before it can be turned NOTE During normal use the red light may illuminate indicating a flue restriction this may be due to a flue obstruction or adverse wind conditions In these circumstances the fan speed will increase and if the condition is not corrected in approximately 10 seconds the gas s...

Page 5: ...ut in the underside of the MATRIX fits over the pilot burner as shown in fig 3 Ensure the REAR MATRIX is positioned in the location stop on the angled legs as shown Ensure the CENTRE MATRIX is positioned in the burner gap and the back lip sits down on the rear burner outlet The loose coal set consists of 4 large FRONT COAL MATRIX square coals and 13 small square coals It is important that these co...

Page 6: ... IN AN EVENLY SPACED ROW 116166 SECTION FIVE POSITION 4 SMALL COALS SO THAT THEY ARE AGAINST THE FIREBACK ONE IN EACH CORNER AND TWO EVENLY SPACED BETWEEN POSITION 4 SMALL COALS SO THAT THEY SIT ON THE HIGH POINTS IN AN EVENLY SPACED ROW The only user removable parts are The loose coals The front coal matrix The centre coal matrix The rear coal matrix Cast Fret Decorative Trim ...

Reviews: