Regency GF950L-2 Gas Fireplace
69
White/Neutral
installation
GF950
12.14.17
3
919-637a
OPTIONAL FAN KIT INSTALLATION
FAN DUCT EXTENSION KIT
In order to use the fan extension duct kit, you must have
fan kit. This kit allows you to extend the fan duct to 9m.
1. Attach the connecting collar to the duct that came with the duct kit.
Use the screws provided.
2. Attach the 4.5m duct within this kit to the connecting collar on the opposite
end with the screws provided. Extend the fl ex to the desired length.
WIRING DIAGRAM
Caution: Ensure that the wires do not touch any hot surfaces
and are away from sharp edges.
Alternate Switches: May use the following. Check with local authorities and electrician.
CLIPSAL 203 2E45 OUD - Dimmer
CLIPSAL 2031 VF3CSF - 3 Speed
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation
Wire Nut
Wire Nut
Wire Nut
Rheostat
Wire Nuts
Wire
Wire
Brown (Hot)
Blue (Neutral)
Copper (Earth)
Earth
NOTE: The wires (in dotted lines)
and the wire nuts are not supplied.
Brown
Black
Black
Blue
White
White
Green
Earth
Heat Wave
Fan Assembly
Fan
~
120 Volts
60 Hz
240 Volts
50 HZ
Red: Low Speed
Black: High Speed
On/Off Switch
FAN DUCT EXTENSION KIT INSTALLATION
White/Neutral
Black: Active - High speed
Summary of Contents for Greenfire GF950L Series
Page 93: ...Regency GF950L 2 Gas Fireplace 93 NOTES notes ...
Page 100: ......
Page 101: ...Regency GF950L 2 Gas Fireplace 101 NOTES notes ...
Page 102: ...102 Regency GF950L 2 Gas Fireplace NOTES notes ...
Page 103: ......