background image

 

 

 

 

 

 

Model Numbers:    MCVP42N, MCVP42NE, MCVP42LP, MCVP42LPE 

Certified to: 

  ANSI Z21.50-2014 • CSA 2.22-2014 

ZERO CLEARANCE VENTED GAS FIREPLACE 

 

 Model Numbers:  MCVP42NH, MCVP42NHE, MCVP42LPH, MCVP42LPHE 

Certified to: 

  ANSI Z21.88-2014 • CSA 2.33-2014 

ZERO CLEARANCE VENTED GAS FIREPLACE HEATER 

 
 

Installation Instructions 

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference. 

A Division of R-Co. Inc. 

2340 Logan Ave.    

Winnipeg, Manitoba Canada 

R2R 2V3  Ph.: (204) 632-1962 

Printed in Canada January 6, 2017  

Part# 42MCVP-MAN14 

For Propane Horizontal installations the 

venting must be an additional one foot 

above the minimum vertical rise off the flue 

before going horizontal. 

 

This appliance may be installed in an 

aftermarket, permanently located, 

manufactured home (USA only) or mobile 

home, where not prohibited by local codes. 

This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases, unless a certified kit is used.

 

 

ATRIUM 

Summary of Contents for Kingsman Marquis MCVP42N

Page 1: ...of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada January 6 2017 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional o...

Page 2: ...ece Driftwood Log Set For use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak L...

Page 3: ...ls 51 Configuration 3 Remote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55...

Page 4: ...keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safet...

Page 5: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Page 6: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Page 7: ...e with the fan off if a fan is present after the curing of the paint has been completed These odours can last upward to 40 hours of burn time keep burning at a minimum of four hours per use until odou...

Page 8: ...onal construction contractors and finishers Frame unit with metal studs minimum 20 gauge Wooden studs may be used but may cause drywall screws to pop or pull due to wood studs drying out Minimum of 1...

Page 9: ...adian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating t...

Page 10: ...e of Fireplace Fireplace to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non C...

Page 11: ...of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs V...

Page 12: ...MCVP42 Locating Your Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12...

Page 13: ...additional one foot above the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Ri...

Page 14: ...commended but optional to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be installed to standoffs only Note Do not drive...

Page 15: ...n Step Two Use Drywall to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Na...

Page 16: ...terial s that will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin...

Page 17: ...iance must be used Carpet hardwood or laminate may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend in minimum Enc...

Page 18: ...cal from top to bottom Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install...

Page 19: ...Glass Heat Deflectors to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may re...

Page 20: ...move Baffle Heater Rated Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Ta...

Page 21: ...o ledge at top of firebox Replace end screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Rep...

Page 22: ...t Area Must Not Be Covered The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMB...

Page 23: ...ate to end of burner tray with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2...

Page 24: ...GT Glass Tray 2 3 4 5 6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damag...

Page 25: ...or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulati...

Page 26: ...GT Glass Tray 2 3 4 5 6 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage o...

Page 27: ...ailure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wo...

Page 28: ...ith GT Glass Tray 2 3 4 5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Page 29: ...s specifically approved with this appliance may result in property damage or personal injury 1 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burner Tray Place...

Page 30: ...ening Remove glass door first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted remo...

Page 31: ...black and red wires at transformer or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEME...

Page 32: ...onged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing contr...

Page 33: ...bjects MQ Glass can be placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channe...

Page 34: ...ce Maximum amount 10lbs on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black...

Page 35: ...be used on some installations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be...

Page 36: ...door in lower latches at an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit...

Page 37: ...glass Wear gloves Removal of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is...

Page 38: ...ny pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any...

Page 39: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Page 40: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Page 41: ...e main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the...

Page 42: ...lot Orifice See Pilot Conversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock mete...

Page 43: ...ector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet fo...

Page 44: ...Gas Conversion for Modulator PART C 44...

Page 45: ...anual Then refer to Burner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it fro...

Page 46: ...Switch Remote Receiver Module IPI Module Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by t...

Page 47: ...press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or D...

Page 48: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Page 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49...

Page 50: ...and Manual HI LO Optional For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as...

Page 51: ...I or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams...

Page 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52...

Page 53: ...e department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 T...

Page 54: ...ic property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust prod...

Page 55: ...ttom of fireplace to center of vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter...

Page 56: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Page 57: ...te comes in two sizes In the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate...

Page 58: ...Thimble Wall Thimble Wall Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall...

Page 59: ...a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge l...

Page 60: ...Clearances in horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60...

Page 61: ...ownward vertical vent runs are NOT permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not b...

Page 62: ...panded 5 Expanded Z58FK8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diame...

Page 63: ...hild Safety Screen Large MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorat...

Page 64: ...0 150MP Hi Temp Millpac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Bra...

Page 65: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Reviews: