W
EB
S
OFTWARE
C
ONFIGURATION
R
EVISED
2018-09-21
CIP™
D
RAWING
N
O
. LP0991-G
2-38
N-Tron
®
Series NT24K
®
Software Manual
Connection State:
This field indicates the state of the connection (established, timed out, closing or
configuring).
RPI:
The field displays the Requested Packet Interval in milliseconds.
Config Assembly:
This field shows the configuration assembly number.
Output Assembly:
This field displays the Output assembly number (the assembly that is sent out from the
switch).
Input Assembly:
This field displays the input assembly number (the assembly that is received into the switch).
Peer Address:
This field shows the peer IP address of the device connected to the switch.
2.12.3
EIP
Indicators
The module status indicator shows the current status of the switch. The network status indicator shows the status
of the EtherNet/IP
™
network interface. These indicators are located on the back of the rack mount version of the
switch or on the front of the CPU module on the DIN-Rail versions of the switch.
Module Status
Network Status
Indicator State
Summary
Description
Steady Off
No power
The switch is not powered up.
Steady Green
Device operational
The switch is operating normally.
Flashing Green
Standby
The switch has not been configured for CIP operations.
Flashing Red
Minor fault
A recoverable minor fault has occurred.
Steady Red
Major fault
A non-recoverable major fault has occurred.
Indicator State
Summary
Description
Steady Off
Not powered, no IP
address
The switch is not powered up, or an IP address has not
been configured.
Flashing Green
No connections
An IP address is configured, but no connections have
been established.
Steady Green
Connected
A connection has been established
Flashing Red
Connection timeout
A connection has timed out.