W
EB
S
OFTWARE
C
ONFIGURATION
R
EVISED
2018-09-21
E
VENT
L
OG
D
RAWING
N
O
. LP0991-G
2-20
N-Tron
®
Series NT24K
®
Software Manual
Note:
The “[End of Events]” message at the end of the file will contain the next sequence number, but that
number will be reused for the next system event on the switch when it occurs.
Boot Count:
A count of how many times the switch has been powered up or restarted.
System Up Time:
The amount of time since the system was started in days, hours, minutes, seconds,
milliseconds.
Time Stamp:
Corresponding date, hours, minutes, seconds, based on the initial value of Current System Time
as defined in the System Configuration View.
Severity:
(most severe to least severe):
Component:
Internal component that generated the event entry.
Event Description:
Description of the event entry.
Emergency:
Major failure, Immediate intervention required
Alert:
Failure of a component, Immediate corrective steps should be taken
Critical:
Partial failure of a component, Immediate corrective action should be taken
Error:
Non-urgent failure
Warning:
Not an error, but may lead to an error if action is not taken
Notice:
Unusual event, but not an error
Informational:
General Information
Debug:
Information useful to a support technician for debugging the switch operation.