R
EVISED
2018-09-21
W
EB
S
OFTWARE
C
ONFIGURATION
D
RAWING
N
O
. LP0991-G
C
ONFIGURATION
N-Tron
®
Series NT24K
®
Software Manual
2-15
•
Keep current PoE Settings:
Retains the existing PoE settings if desired. (PoE models only).Keep
current Port Security Settings: Retains the existing Port Security settings if desired.
Note:
When the configuration is loaded from the Configuration Device, it must be saved for it to be available if
the Configuration Device is removed.
Note:
When the switch is shipped, it does not have a “configuration file” since the unit is using the factory
defaults. Before a configuration can be customized, click on the
Save
button in order to create the file.
Configuration
Fault
When the switch is booted and misconfigured settings are detected, a Configuration Fault will be triggered and the
configuration may not be saved. This can occur when updating system firmware where settings permitted in the
previous release may no longer be permitted. In this case, the
Save
button will be replaced with a
Show Errors
button (as seen below) and the misconfigured settings must be fixed before the configuration may be saved.
Show Errors:
Click on the
Show Errors
button to view the current configuration and display any detected errors.
This button is only visible when there is a settings misconfiguration.