The illuminator has two modes;
1.
Programming Mode when the remote control can be used and
2.
Operating Mode when most of the remote control functions are disabled. The
only remote control functions that can be used in Operating mode are; Enable/
Disable Status LEDs, Disable Manual Buttons and PIN entry.
Manual Buttons are always available in programming mode or if they have been
disabled, they can be enabled in programming mode.
Manual Buttons are available in operating mode, provided they have not already
been disabled.
The number of button pushes indicated above are based on the user starting with the
illuminator in either programming or operating mode.
If no buttons are pressed within 2 minutes then the illuminator will automatically
default back into the previous mode it was in – programming or operating mode.
Action Required
Step 1: LHS
Button
LHS LED
Step 2: RHS
Button
RHS LED
Comment
Disable / Enable
Manual Buttons
1 x Long Push
(4s), then 2 x
Short
Push
Flashing
Amber
Push to cycle
Disable / Enable
Disable - Red
Enable - Green
Buttons will be
disabled 30 minutes
after this selection is
made - This is to allow
the user to re-enable
manual buttons if
required
Full Re-set
(Including PIN re-set)
Keep both
buttons
depressed during
power up - LEDs
will both flash
Amber
Flashing
Amber
then solid
Green
after
button
release
Keep both
buttons
depressed
during power up
- LEDs will both
flash Amber
Flashing Amber
then Flashing
Amber after
button release
illuminator will revert to
Programming Mode,
full factory default
including No PIN