Manual Button Operation
Buttons are accessed by removing the base plate at the bottom of the unit. The
number of button pushes indicated below are based on the user starting with the
illuminator in either programming or operating mode.
Action Required
Step 1: LHS
Button
LHS LED
Step 2: RHS
Button
RHS LED
Comment
Power Adjust
1 x Push
Solid
Red
Each push
cycles through
power levels
Green Flashes
indicate level.
High power (5
Flashes) to Low
power
(1 Flash)
Photocell Adjust
2 x Push
Solid
Green
Each push
cycles through
photocell levels
Green Flashes
indicate 3
sensitivity
settings:
Low: 1 Flash
Med: 2 Flashes
High: 3 Flashes
Solid Red
for Photocell
disabled.
Status Indicator
LEDs On/Off
3 x Push
Solid
Amber
Each push
cycles between
On and Off
On - Green
Off - Red
Factory Re-set
(Does not Re-set PIN)
1 x Long Push
(4 Seconds)
Flashing
Red
Push and Hold
until both LEDs
Flash Amber
Solid Red - After
4s both LEDs
Flashing Amber
Reverts to
Programming Mode
unless a PIN is
present. If a PIN is
present reverts to
original mode before
re-set
Disable Remote
Control
Change between
Programming Mode
and Operating Mode
1 x Long Push
(4s), then 1 x
Short
Push
Flashing
Green
Push to cycle
Disable / Enable
Disable - Red
Enable - Green
Reverts to the Mode
requested unless a
PIN is present and you
are in Operating Mode
you cannot change
to programming
Mode. Disable remote
(enter OP Mode) or
Enable remote (enter