10
rayteccctv.com
Raytec Global Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Reset
Settings Re-set:
Pressing and holding the RESET BUTTON on the remote control
(Programming Mode Only) or using the manual buttons to complete a RESET will
restore the factory settings to the illuminator. Note: It will not remove a PIN if one
is present.
Full Re-set:
Re-cycling the power whilst pressing both manual buttons will restore
factory settings and remove a PIN if one is present.
Both indicator LEDs flash amber for both above re-sets when complete.
VARIO2 Quick Troubleshoot
•
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe
working practices are followed at all times.
•
Check polarity of illuminator connection red=+ve, black=-ve
•
Ensure power is 12-24V AC or DC (For Vario 16 variants :
24V only AC or DC
)
•
Ensure telemetry wires are shorted out or valid telemetry input (zero volt or TTL)
is applied and correctly wired
•
Check photocell is working. Cover photocell fully, light should turn on if valid
telemetry input. It is sometimes difficult to see Infra-Red illuminators working in
high brightness conditions.
•
Ensure power supply is suitably rated to product - check page 3 for specifications
•
If longer cables used, ensure sufficient voltage is provided to allow for drops
across the cable