Programming mode
– LHS Green Solid RHS LED flashes AMBER 1 sec on/off
Operating mode
– LHS Green Solid
Status LEDs can be turned off in either mode – check if no LEDs visible.
LHS SOLID GREEN:
LHS FLASHING GREEN:
RHS FLASHING AMBER:
RHS SOLID AMBER:
LHS FLASHING RED:
LHS SOLID RED:
The fault indications are non latching.
•
Check unit is responding to remote /Manual Control buttons. If not..
•
Status indicators may be turned off. Turn on with remote or with manual
buttons. This can be done even if programming has been disabled.
•
In extreme sunlight conditions, distance between remote and unit may need
to be reduced.
•
Programming may be disabled. Enter PIN to retrieve control or RESET
illuminator using one of the two RESET modes.
•
Battery failure. Check battery on remote (CR2025). Test 3 volt battery, replace
if necessary. Ensure battery has clean contacts.
•
Remote failure. Test with new remote.
NOTE
: the if there is a voltage supply error, the LHS LED will FLASH RED but
extinguish and revert to the standard SOLD GREEN when the correct voltage has
been restored.
Power Applied
Remote control IR receiver problem
Indicates unit is in programming mode
Indicates that a valid command is being received
Voltage supply problem detected
Illuminator fault detected