89
SCC
Edition 10-2008a
Function test SCC
Fan motor bottom:
- Select RPM with central dial
(default: second highest RPM):
- Typ 61:
500,1100,1550,1650
- Typ 62, 101, 201:
500,1250,1800,1900
- Typ 102, 202:
550,1450,2000,2200
- Activat. of solenoid valve lling Y1
- Level electrode shows 1 = steam generator lled
- Level electrode shows 0 = steam generator partial lled
- Activation of SC Pump M4
- Level electrode shows 1 = steam generator lled
- Level electrode shows 0 = steam generator partial lled
- Activation of solenoid valve quenching Y2
- Indication of actual temperature B2
(needed for testing quenching system).
- Activation of solenoid valve moistening Y3
10 - Function Test
Solenoid moistening Y3
0 - 1
9 - Function Test
Solenoid quenching Y2
1 - 0
Temperature B2
36°C
8 - Function Test
SC Pump M4
1 - 0
Level electrode
1 - 0
7 - Function Test
Solenoid valve lling Y1
1 - 0
Level electrode
1 - 0
6 - Function Test
Fan motor bottom
Speed 4
1900rpm
actual speed
xxxx
Start
Start
Start
Start
Start
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...