9
CM
Edition 10-2008
Water level control Steam Generator
V
AC
S2
M4
Y1
Y2
B2
S2
B5
F3
Center S2 ==> Ground:
2 - 6V AC:
water level too low
steam heating must switch OFF
solenoid
valve
lling
Y1
ON
Center S2 ==> Ground:
0V AC:
water level reached
steam heating can switch ON
solenoid valve lling Y1 switched OFF
Every 2 minutes steam elements will switch off for
water level control
PCB
X12
1 2 3 4