Clima Plus Control SCC
The calculated humidity inside the cabinet is based on:
1. Voltage output signal P1 (depending on fan motor speed, ref: function test #5)
2. Temperature B4 (thermocouple behind motor mounting plate)
3. RPM signal of the fan motor (via BUS signal)
The offset voltage of P1 (Motor not turning) is appr.: 0.45 - 0.55V
Basic rule:
The less humid, the higher is the voltage of P1,
The higher the rpm, the higher the voltage of P1.
Example: SCC 101 E
RPM
P1 (approx. Volt)
Dry
1,1
Speed 500rpm
Wet
0,7
Combi
0,6
Dry
2.3
Speed 1250rpm
Wet
1.7
Combi
1.5
Dry
2.9
Speed 1800rpm
Wet
2.4
Combi
1.9
Dry
3,1
Speed 1900rpm
Wet
2.5
Combi
2.2
Thermocouple
humidity control
rpm measurement
RPM
B4
Differential pressure sensor
ClimaPlus
P1
Clima Status (approx. value in Pascal)
Indicated values shall NOT be “0” or “85000”
If “0” or “85000” is indicated
re-calibration is needed
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...