162
Trouble shooting SCC
Edition 10-2008a
Service 42 (Y4)
Solenoid valve Y4 defective or feeding hose to care container blocked
CDS does not send any pulses
Display Service 42
No
No
Yes
Operate Solenoid valve
Y4 in function test 10.1
In function test 10.1
check voltage 230V
at coil solenoid valve Y4
Logic error;
Check plugs and cables or chan-
ge I/O pcb
Change triple solenoid
50.01,.050
Solenoid valve opens
Check Voltage input
at I/O pcb X21
Yes
Check voltage on auxilliary
contact K1
No
Yes
Check CDS sensor
Yes
Reset error by starting Cleanjet
program; Wait 5 min. Swtich unit
OFF and ON and start cleanjet
abort program
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...