70
SCC
Edition 10-2008a
16 - DIAGNOSTIC
Clima Status
Cal. Speed 1
Error
xxx
rpm
---
Dry
Wet
Combi
xxxx
xxxx
xxxx
Diagnostic mode SCC
16.1 - DIAGNOSTIC
Cal.Geodat
Auto. Calibration
-1.0000
1.0000
m.val
a.val
ON
17 - DIAGNOSTIC
Clima Motor
M3
0 - 1
S4
1 - 0
18 - DIAGNOSTIC
Hot Air
50%
19 - DIAGNOSTIC
Steam
100%
- Display of calibration values relative to the different motor
speeds and unit size;
- Normal values between 72000-130000
Automatic Humidity calibration
AFTER manual calibration this feature is set to „OFF“.
Do not reset to „ON“ after manual calibration.
When „ON“ Autocalibration will be done when cabinet is cold
and the steam generator is preheating;
1.0000 is only shown when autocalibration is „OFF“
M3: Motor ClimaPlus Flap
S4: Micro switch ClimaPlus ap
No steam production, when S4 is „0“ => open!
possible values:
0:
hot air heating off
50%: hot air heating 50%
100%: hot air heating 100%
possible values:
0:
steam heating off
50%: steam heating 50%
100%: steam heating 100%
RESET
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...