155
Trouble shooting SCC
Edition 10-2008a
Service 10 (SC Pump)
Level electrode of the steam generator did not recognise a reduction
of the water level during last SC-Automatic
Indication Service 10
Activate function test
Select step 8
SC Pump M4
and touch „Start“ key
Check pump for scale deposits or
other dirt, that blocks the impeller
Clean housing of the pump, desca-
le steam generator
and /or change pump
Short circuit level electrode or
check drain system and quenching
box for dirt,
clean if necessary
Check cable, connector and
pump. Change defective part
Change auxiliary contact or
contactor
Change I/O-pcb
Change fuse
Check cable and pump for short
circuit
YES
YES
YES
NO
NO
NO
YES
NO
Pump active, water is pum-
ped off
230V output at I/O-pcb
X18 1/2 during function test?
Auxiliary contact 13/14 of
contactor K1 ok?
Fuses F6/F6.1
(on I/O pcb) ok?
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...