CM - Sequence of events
Mode: Low temperature steam;
Temp. range 30-99°C (86-210°F)
Function Step
Responsible sensor
1. Select Low temperature steam mode
Set temperature 30-99°C (86-210°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Check water level inside steam generator
Level electrode S2 inside Steam Generatorr
5. Time based preheating of steam generator,
Thermocouple B5 inside Steam Generator
if B5 is below 85°C (185°F);
6. Timer starts after successful preheating
Logic on PCB
(blinking dot in Display)
7. Steam supply until set temperature
Cabinet sensor B1
inside cabinet is reached
8. Hot Air supply (only 50%) when set
Cabinet sensor B1
temperature can not be reached in time
by Steam alone
9. Quenching (set to 70°C/158°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual temperature is 2°C / 4°F higher than the set temperature for longer than 2
minutes, the fan speed will be reduced automatically.
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...