50
SCC
Edition 10-2008a
It is possible to abort the cleanjet program. However the abort program of 30min. can not be short-
ened again as the steam generator must be neutralised from possible remaining care solution.
Cleanjet Abort program
During the abort program the steam generator will first be filled with Y1. After draining the steam eg-
nerator it will be filled a second time to a level above the level electrode. After a second draining the
steam generator will fill again exactly to the level electorde.
In case the level electrode does not recognise the water Error 120 will be shown.
At the end of the abort program a short steam period and rinsing the cabinet with Cleanjet pump will
follow.
The duration of steam heating time unitl next SC automatic is now 120min (units with index “G”) .
However should the steam generator develop scale because the customer does not use the care
tabs, this time will automatically be reset to 60 minutes.