CM - Sequence of events
Mode: Finishing;
Temp. range 30-300°C (86-572°F)
Function Step
Responsible sensor
1. Select Finishing mode
Recommended
temperature
30-300°C (86-572°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Check water level inside steam generator
Level electrode S2 inside Steam Generator
5. Time based preheating of steam generator,
Thermocouple B5 inside Steam Generator
if B5 is below 85°C (185°F);
6. Timer starts after successful preheating
Logic on PCB
(blinking dot in Display)
7a. Electric units: alternating
12 sec. Hot Air
Cabinet sensor B1
6 sec. Steam
Quenching sensor B2
7b Gas units: alternating
30 sec. Hot Air
Cabinet sensor B1
15 sec. Steam
Quenching sensor B2
8. Quenching (set to 70°C/158°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual
temperature
in the range of
30-99°C
(86 - 210°F) is 2°C / 4°F higher
than the set temperature for longer than 2 minutes, the fan speed will be reduced automati-
cally.
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Summary of Contents for SCC Series
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...