Trouble shooting SCC
Edition 10-2008a
Service 41 (Y3)
Solenoid valve Y3 defective of moistening nozzle blocked;
CDS does not send any pulses;
First time display: Descale moistening nozzle, Second time display: Servcie 41
Display Service 41
NO
YES
Operate Solenoid valve
Y3 in function test 10
In function test 10
check voltage 230V
at coil solenoid valve Y3
Logic error;
Check plugs and cables or
change I/O pcb
Check Voltage input
at I/O pcb X21
YES
Check voltage on auxilliary
contact K1
NO
Moistening nozzle blocked
YES
Descale nozzle
NO
NO
Change triple solenoid
50.01,.050
Solenoid valve opens
YES
Check CDS sensor
YES
Reset error by starting Cleanjet
program; Wait 5 min. Swtich unit
OFF and ON and start cleanjet
abort program