Remote Commands to Perform Measurements with I/Q Data
R&S
®
FSV/A3000 I/Q
Analyzer
258
User Manual 1178.8536.02 ─ 01
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
This command queries the results of the band power measurement.
Suffix:
<n>
.
<m>
Return values:
<Power>
Signal power over the marker bandwidth.
Example:
Activate the band power marker:
CALC:MARK:FUNC:BPOW:STAT ON
Select the density mode for the result:
CALC:MARK:FUNC:BPOW:MODE DENS
Query the result:
CALC:MARK:FUNC:BPOW:RES?
Response:
20dBm/Hz
Usage:
Query only
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:SPAN
<Span>
This command defines the bandwidth around the marker position.
Suffix:
<n>
.
<m>
Parameters:
<Span>
Frequency. The maximum span depends on the marker position
and R&S
FSV/A model.
*RST:
5% of current span
Default unit: Hz
Example:
CALC:MARK:FUNC:BPOW:SPAN 2MHz
Measures the band power over 2 MHz around the marker.
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
<State>
This command turns markers for band power measurements on and off.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 0 | 1
I/Q Analysis