Basics on I/Q Data Acquisition and Processing
R&S
®
FSV/A3000 I/Q
Analyzer
24
User Manual 1178.8536.02 ─ 01
MultiMode
setting
Offset compensation
Offset compen-
sation range
Application
P-Mode
DC voltage at positive
input terminal
±24 V
Measurement of single-ended AC signals
with high superimposed DC component at
the positive input terminal.
Note
: The maximum voltage difference
between the positive and negative input ter-
minals is 16
V.
N-Mode
DC voltage at negative
input terminal
±24 V
Measurement of single ended AC signals
with high superimposed DC component at
the negative input terminal.
Note
: The maximum voltage difference
between the positive and negative input ter-
minals is 16
V.
If the offset for DM-mode or CM-mode is changed, the offsets for the P-mode and N-
mode are adapted accordingly, and vice versa.
4.3
Basics on External Generator Control
Some background knowledge on basic terms and principles used for external genera-
tor control is provided here for a better understanding of the required configuration set-
tings.
External generator control is only available in the following applications.
●
Spectrum Analyzer
●
I/Q Analyzer
●
Analog Demodulation
●
Noise Figure Measurements
External Generator Connections
.............................................................................24
Overview of Supported Generators
.........................................................................27
.............................................................................................28
............................................................................................29
Reference Trace, Reference Line and Reference Level
.........................................31
....................................................................................... 31
Displayed Information and Errors
............................................................................34
4.3.1
External Generator Connections
The external generator is controlled either via a LAN connection or via the EXT. GEN.
CONTROL GPIB interface of the R&S
FSV/A supplied with the option.
Basics on External Generator Control