IQ3 Street Logger Dash Installation Manual
41
Bar Graph (Sweep Tach)
Gear Indicator (center of dash) “Gear Position”
Function
Description
Channel To Display
Pull down arrow selects sensor channel
Averaging Filter
Smooths displayed data. 10 is default
Display Mode
Selects when to display the gear number in
the center display.
OK
Closes window following programming changes
Remaining Inputs
As shown above, to program an input area, simply locate the desired sensor channel by use of
the pull down arrow, select the sensor channel, then define the remaining values for Decimals to
Display, etc.
Function
Description
KPH MPH RPM
Selection defines channel name on dash
Channel to
Display
Pull down arrow selects channel for bar graph
data
Averaging Filter
Smooths displayed data. 10 is default
Minimum Value
Determines starting point for bar graph
Maximum Value
Determine ending point for bar graph
Tag Start Value
Determines start value for bar graph
Tag Value per 10
Bars
Determines value for each 10 bar segment. There
are a total of 8, 10 bar segments for 80 total bars.
Channel tag value must be equally divisible by the
80 bars to correspond correctly with a channel’s
actual reading.
OK
Closes window following programming changes
Function
Description
Channel to Display
Pull down arrow selects sensor channel
Decimals to Display
Number of digits to display after decimal
Averaging Filter
Smooths displayed data. 10 is default
Channel Tag Text
Name/channel label to be displayed. 5
total characters