IQ3 Street Logger Dash Installation Manual
29
Fuel Level
The table below shows the (8) eight different types of fuel senders supported. If you are not sure
of the type you are using you will have to measure the resistance with an ohms meter or for best
accuracy use the custom setting. See Setup Mode below.
ONSCREEN
NAME
Resistance
Empty - Full
Typical Application
240 - 33 OHM
240 - 33 Ohms
Stewart Warner senders
90 - 0 OHM
90 - 0 Ohms
Toyota, Nissan
73 - 10 OHM
73 - 10 Ohms
Most Ford Prior to 1986 & Chrysler
40 - 250 OHM
40 - 250 Ohms
Most General Motors 1998 to present
16 - 158 OHM
16 -158 Ohms
Most Fords 1987 to present
10 - 180 OHM
10 - 180 Ohms
VDO senders
0 - 90 OHM
0 - 90 Ohms
Most General Motors 1965 to 1997
0 - 30 OHM
0 - 30 Ohms
Most General Motors pre -1965
User Cal
Custom user scale
0 - 5 volts
0-5 volt input, must use software to program, Raw Data A, Raw
Data B, Min, Max Result Values
Custom Fuel Level Calibration Procedure:
1)
Empty the fuel tank to the level you wish to call 0%
2)
Turn on the dash and enter setup mode 1 by entering a MEDIUM press on the button 1
3)
The Dash will display SETUP 1?, accept that you wish to enter setup 1 by once again
entering a SHORT press on the button 1
4)
Step through the setup parameters by entering a SHORT press on the button 1 until you
reach the SENS FUEL parameter in the lower left LCD position
5)
You can then step through the available fuel sensors by entering a SHORT press on
button 2 to reach the USER CAL setting
6)
Enter a SHORT press on the button 1 to select User Cal, CAL FUEL LEVEL N will be
displayed
7)
A SHORT press on button 2 will change the N to Y to initiate custom calibration
8)
A SHORT press on button 1 will accept Y selection
9)
Empty Voltage will be displayed. The unit uses a internal pullup resistor to convert the
resistance to voltage as shown
10)
Enter a SHORT press on the button 1 to set the tank’s empty value; the dash will advance
to the next step.
11)
Full Voltage will be displayed. Fill tank to the Full position. The voltage will change
accordingly. Once the tank is full and the voltage stabilizes, enter a SHORT press on the
button 1 to set the tank’s full value.
12)
Enter a LONG press on the button 1 to save settings and exit setup mode