3156B User Manual
Racal Instrument © 2005
Specifications A-3
Amplitude Characteristics
Amplitude
20mV to 20Vpk-pk, output open circuit
10mV to 10Vpk-pk, into 50
Ω
Resolution 4
digits
Accuracy (measured at 1kHz)
1V to 10Vpk-pk: ±(1% + 25mV)
100mV to 1Vpk-pk: ±(1% + 5mV)
10mV to 100mVpk-pk: ±(1% + 2mV)
DC Offset Range
0 to ±4.995V
DC Offset Resolution
1mV
DC Offset Accuracy
±(1% ± 1% from Amplitude ±5mV)
Run Modes
(applies for Standard, Arbitrary, Sequencer and Modulated waveforms)
Continuous Mode
Continuous output of a waveform after a software or
hardware Enable ON command. Continuous mode
disabled with software only Enable OFF command
Triggered Mode
Output of one waveform cycle following an Enable
ON command. Last cycle always completed
Burst Mode (does not operate in
Sequencer Mode)
Output of a single or multiple pre-programmed
number of waveform cycles (burst) starting after a
software or hardware Enable ON command.
Counted Burst Cycles
1 to 1Meg, programmable
Burst Limitations
For segments below 8 points: Segment duration
must be >500ns
For segments Above 8 points: Segment duration
must be >40ns
Gated
Mode
Hardware or backplane transition enables or
disables generator output. Last cycle always
completed
Run Modes Enable Source
Software: Enable ON/OFF command