3156B User Manual
WaveCAD 4-18
Racal Instrument © 2005
The Sequence Table is demonstrated in Figure 4-7. To access the
Sequence table, click anywhere on the Sequence Table area. If it was
not yet, it will turn white as opposed to the Segment Table area that
turns gray.
Figure 4-7 The Sequence Table
There are three major elements that you should consider while
programming a sequence table. They are: Link, Seg# and Loops.
These terms are explained below.
Link
- This parameter defines an index array for the sequence
generator. When generating sequences, the instrument steps though
the links in descending order therefore, make sure that you enter your
waveform segments in exactly the order you would like them at the
output.
Seg #
- This parameter associates waveform segments with links. You
can use different segments for different links or you can use the same
segment for a number of links. There are no limitations how you
associate links to segments, except you cannot program in the
sequence table segments that were not defined earlier.