3156B User Manual
Racal Instrument © 2005
WaveCAD 4-49
Max. Peak Deviation
– This parameter defines the forward peak
deviation. Note that the forward peak deviation cannot exceed the pre-
defined Deviation parameter as shown on the Toolbar. In case you
need to exceed the pre-defined peak value you must quit this box and
modify the Deviation parameter to provide sufficient range for the
forward peak deviation range.
Figure 4-25 Generating Sine Modulation Using the FM Composer
Min. Peak Deviation
– This parameter defines the backwards peak
deviation. Note that the backwards peak deviation cannot exceed the
pre-defined Deviation parameter as shown on the Toolbar. In case you
need to exceed the pre-defined peak value you must quit this box and
modify the Deviation parameter to provide sufficient range for the
backwards peak deviation range.
Cycles
– The Cycles parameter defines how many sine cycles will be
created within the specified start and end anchor points. The example
below shows three sine cycles.