9.1 Battery Charging
To charge the wheelchair batteries:
• Connect the charger plug into the battery charger socket on
the R-Net JSM.
• You will not be able to drive the wheelchair when the charger
is connected.
• To connect the charger plug, ensure the single pin is at the
bottom, as shown in Fig 9.0, then offer the charger plug to the
R-
Net in a horizontal orientation.
• The molded guide on the R-Net will help you to locate the
plug. Ensure the plug is pushed fully in
to
position.
WARNING!
• Do not exceed the maximum charging current of 12A-rms.
Always use an off-board charger fitted with a Neutrik NC3MX
plug. Failure to observe these conditions could result in poor
contact resistance in the charger connector resulting in
overheating of the charger plug. This presents a potential burn
hazard for the user. Sunrise Medical accepts no liability for
losses of any kind arising from failure to comply with this
condition.
• Do not disconnect batteries or open-circuit the circuit breaker
while charging is in progress. Failure to observe this condition
could result in a burns hazard or fire hazard.
• Sunrise Medical accepts no liability for losses of any kind
arising from failure to comply with this condition.
WARNING!
• Battery chargers are only intended to charge 24V; Group 22,
Group 24, and Group 34; Lead Acid or Gel style batteries.
• Only use the battery charger that has been supplied with your
wheelchair.
• The use of incorrect chargers could damage the batteries,
wheelchair, control system or charger itself, or may result in
parts overheating creating the potential for burns or even fire.
• Sunrise Medical accepts no liability for losses of any kind if
the
charger used is incompatible with the control system or any
other part of the wheelchair system.
• When charging the battery charger can become hot and could
potentially cause a burn.
For comprehensive instructions and advice on
Batteries
and
Battery Charging, please consult
your wheelchair Owner’s Manual and the
Owner’s Manual supplied with the Battery
Charger.
9.0 The Charger Socket
Charger Plug
Single Pin to Bottom
Charger Socket
Fig.9.0
DANGER!
249044 Rev. A
30
R-Net Control System w/Omni2
Summary of Contents for R-net
Page 1: ...Instructions for Use R Net Control System R Net Controls P N 249044 Rev A ...
Page 7: ...LED and CJSM1 249044 Rev A 7 R Net Control System w Omni2 ...
Page 34: ...Omni2 249044 Rev A 34 R Net Control System w Omni2 ...
Page 76: ...CJSM2 249044 Rev A 76 R Net Control System w Omni2 ...
Page 105: ...249044 Rev A 105 R Net Control System w Omni2 ...
Page 107: ...249044 Rev A 107 R Net Control System w Omni2 ...