Scalar i6000 Installation Guide Super Doc
33
Connecting the Aisle Cable Assembly
The aisle cable assembly connects the power rails to the SPA/SCC mount assembly. It comes installed in
the left parking module so all you need to do is connect it to the SPA/SCC mount assembly. The aisle cable
assembly is mounted on the left parking module firewall and its two connectors connect into the two power
rail connectors in the left parking module (see
Figure 15
).
Required tools: 2.5 mm hex wrench
Required equipment: Two M4X10 socket head cap screw low profile screws
Figure 15
Cable Aisle Assembly Installed in Left Parking Module
1
Go to the back of the left parking module. The end of the aisle cable assembly should be visible in the
open area above the power chassis.
2
Route the cable into the control module through the rectangular cutout in the left parking module wall,
then up and over the lower drive bay in the control module.
3
Plug the cable into the lower right connector on the SPA/SCC Mount Assembly (see
Figure 16
).
Two screws in
mounting plate
Connect aisle cable
assembly connectors
to power rail
connectors
Power rail