Appendix A: DXi4000 System Specifications
Quantum DXi4000 User’s Guide
253
Table 10 Environmental
Specifications
Climatic Environment
Temperature and
Altitude
Operating
10 to 35 °C (50 to 95 °F) 35 °C Max, Altitude =
900 m or 2952.75 ft (28 °C Max, Altitude =
3048 m or 10,000 ft)
Shipping and storage
-40 to 65 °C (-40 to 149 °F) up 12,000m
(39,370 ft)
Relative humidity
Operating
20% to 80% (non-condensing)
Shipping and storage
5% to 95% (non-condensing)
Vibration and Shock
Operational Shock
Peak Acceleration
31G
Duration
2.6 milliseconds
Wave Shape
½ Sine
Operational Vibration
Mode
Random Vibration
Frequency Range
5Hz–350Hz
Amplitude
0.26Grms
Application
Operational Orientations
Shipping and Storage
Mode
Random Vibration
Frequency Range
10Hz–250Hz
Amplitude
1.54 Grms
Rate/Duration
(PSD can be provided) 15 minutes all
operational orientations
Acoustic
Acoustic output
Operating
< 67 dBA at 1 meter, room temperature (20C)
Agency Approvals
Safety
IEC 60950-1 (ed. 1), CSA 60950-1-03/UL 60950-1 1st Edition
Summary of Contents for DXi4510
Page 1: ...User s Guide Quantum DXi4000 6 67092 03 Rev A...
Page 16: ...Tables xvi Quantum DXi4000 User s Guide...
Page 24: ...Preface xxiv Quantum DXi4000 User s Guide...
Page 42: ...Chapter 1 DXi4000 System Description Network Segmentation 18 Quantum DXi4000 User s Guide...
Page 52: ...Chapter 2 Basic Operations Locating Serial Numbers 28 Quantum DXi4000 User s Guide...
Page 272: ...Chapter 10 DXi4000 Utilities Reboot Shutdown 248 Quantum DXi4000 User s Guide...
Page 288: ...Appendix B Troubleshooting Common Problems and Solutions 264 Quantum DXi4000 User s Guide...