Operation Guide Revision 3.7c
©1994 - 2003 Quantec® Tonstudiotechnik GmbH, Munich, Germany
82
Step 4- only when necessary
If the automatic synchronization to the SDIF-2 preambles does not allow satisfactory sound quality
to be transmitted, the frames must be adjusted manually. The mode
MAN Prbl Bad
should be
used when testing, as errors are not muted and can be clearly heard in this mode.
In the submenu item
Set RX Sync Position
the window of the receiver buffer can be
adjusted until a flawless audio signal can be discerned. Again: pay careful attention to the level
errors in the 6dB frames, and check again with a change of sample rate and with varispeed.
An error free connection is normally reached in a range of 6 to seven steps. The value to be saved
should lie in the middle of this range.
And if it still doesn’t work ? There could be errors in the configuration of the »send« path (see step
2). If the audio signal is faulty at the input of the SDIF-2 device, no adjustment made here will
solve the problem…
Step 5- Only when necessary
The mode
MAN Prbl Mrg should now be used to test if at least one
valid SDIF-2 preamble is present, which could be used to cause the
audio to mute if input signals are missing. It is necessary to
activate MAN Prbl Mrg
for this to work.
If no other modifications have been made and the audio signal can still be clearly heard, the
preamble is fine. Monitor (again!) with a change of sample rate and with varispeed. If everything is
OK, the mode
MAN Prbl Mrg
should now be saved.
However, if you now feel: »It was working a minute ago and now it’s dead!.« go back to
MAN
Prbl Bad
and save this mode.
Summary of Contents for Zombies 12xx Series
Page 1: ...1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany ZOMBIES 12xx Operation Guide...
Page 4: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 4...
Page 8: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 8...
Page 11: ...1 Introduction ZOMBIEs 12xx 11...
Page 18: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 18...
Page 34: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 34...
Page 60: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 60...
Page 68: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 68...
Page 84: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 84...
Page 90: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 90...
Page 126: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 126...
Page 135: ...Revision 0 7 1994 1999 QUANTEC Tonstudiotechnik GmbH Munich Germany VI...
Page 141: ...Status 10 98 1994 1999 QUANTEC Tonstudiotechnik GmbH Munich Germany XII...