Operation Guide Revision 3.7c
©1994 - 2003 Quantec® Tonstudiotechnik GmbH, Munich, Germany
72
Unit:
Samples
with FINE DELAY
without FINE DELAY
GL>LL Del.(Samp)
A
B
: 131071.00+21
GL>LL Del.(Samp)
A
B
: 6
Selecting
Samples
enables the
FINE DELAY to be displayed in units of
1
/
100
Sample. The
delay value shown does not include the internal propagation delay (due to the buffers and normal
input-to-output delay) and should be increased by this value, which is displayed on the bottom right
of the display (here
+21 or +6
samples respectively).
Unit:
S525
with FINE DELAY
without FINE DELAY
GL>LL Del.(S525)
A
B
: 2:21:1471+21
GL>LL Del.(S525)
A
B
: 2:21:1471 +6
The unit
S525
is ideal for use when compensating frame buffer transport delay in video
technology with 30
F
/
S
(or 29.97
F
/
S
)
.
Therefore the FINE DELAY readout is not necessary. The
readout is in the form seconds: frames: samples. Again, the delay value shown should be increased
by the value of the internal propagation delay (due to the buffers and normal input to output delay)
which is displayed on the bottom right (here
+21
or
+6
samples respectively).
Unit:
PAL
with FINE DELAY
without FINE DELAY
GL>LL Del.(PAL)
A
B
: 2:18:0511+21
GL>LL Del.(PAL)
A
B
: 2:18:0511 +6
The unit
PAL
is ideal for compensating frame buffer transport delay in
video technology with
25
F
/
S
.
Therefore the FINE DELAY readout is not necessary. The readout is in the form seconds:
frames: samples. As usual, the delay value shown should be increased by the value of the internal
propagation delay (due to the buffers and normal input to output delay) which is displayed on the
bottom right (here
+21 or +6
samples respectively).
Summary of Contents for Zombies 12xx Series
Page 1: ...1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany ZOMBIES 12xx Operation Guide...
Page 4: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 4...
Page 8: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 8...
Page 11: ...1 Introduction ZOMBIEs 12xx 11...
Page 18: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 18...
Page 34: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 34...
Page 60: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 60...
Page 68: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 68...
Page 84: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 84...
Page 90: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 90...
Page 126: ...Operation Guide Revision 3 7c 1994 2003 Quantec Tonstudiotechnik GmbH Munich Germany 126...
Page 135: ...Revision 0 7 1994 1999 QUANTEC Tonstudiotechnik GmbH Munich Germany VI...
Page 141: ...Status 10 98 1994 1999 QUANTEC Tonstudiotechnik GmbH Munich Germany XII...