74
User Manual Version 3.1
Figure 35: Adjusted encoder
Pos: 81.29 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1303_ADJUSTMENT STEPS @ 0\mod_1254483974277_912.doc @ 4053 @
ADJUSTMENT STEPS
Pos: 81.30 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü4_130301_PRINT CORR. PATT._Systeme @ 1\mod_1255700246238_912.doc @ 6673 @
PRINT CORR.PATT.
This correction pattern is a test printout which allows the user to detect easily the right
correction offset. By pressing the Ok key, the printer asks for the available paper source.
After choosing between the options “
Feeder
” (the feeder will dispense one sheet of paper)
or “
Manual
” (the user has to put on paper manually) the printer will start the test print.
This kind of calibration may become necessary since a completely tolerance-free production
of a print unit is not possible. Slight deviations due to manufacturing tolerances can be
balanced via the software of the control device. Calibration can only be carried out at the
installed device and can therefore not be performed by the manufacturer.
Figure 36 shows an example of this correction pattern. Each column of the printout
represents a possible correction value. The user has to choose the pair of bars that matches
best. The number above the chosen column represents the correction value for the
unit/cartridge combination of the correspondent row (please note that already entered
correction values will not have any effect on this test pattern. The test printout is used as a
reference to detect offsets between the units/cartridges).