User Manual Version 3.1
77
Recommended adjustment sequence
First verifying that the proper distance values (
DIST. U1-U2, DIST.
U2-U3, DIST. U3-U4
, in the
PRINTER CONFIG. > DISTANCES
menu)
have been set between print units.
Then provide the fine adjustments by setting the offset values
"between print units" (
CORR. U1-U2, CORR. U2-U3, CORR. U3-U4
)
before adjusting the offset values "between cartridges" (
CORR. U1
C1-C2, CORR. U1 C2-C3
) within a print unit.
Pos: 81.37 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü4_130307_CORR. U1 C2-3 @ 0\mod_1254842367442_912.doc @ 4657 @
CORR. U1 C2-C3
The (horizontal) correction between the cartridges
C2
and
C3
of print unit
U1
can be set in
the same way as described in
CORR. U1 C1-C2
.
Default:
0
Pos: 81.38 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü4_130309-130310_CORR. U2 C1-2 / U2 C2-3 / U3 C1-2 /U3 C2-3 / U4 C1-2 / U4 C2-3_AS-2060/Orbit/OrbitB @ 0\mod_1254908701962_912.doc @ 4791 @
CORR. U2 C1-C2
(Will only be displayed in systems with 2 and more print units).
Same function as in
CORR. U1 C1-C2
.
Default:
0
CORR. U2 C2-C3
(Will only be displayed in systems with 2 and more print units).
Same function as in
CORR. U1 C1-C2
.
Default:
0
CORR. U3 C1-C2
(Will only be displayed in systems with 3 and more print units).
Same function as in
CORR. U1 C1-C2
.
Default:
0