User Manual Version 3.1
93
on print base
SET
TIME[s]
on 3rd party belt
SET
TIME[s]
downstream from the printer.
on print base
Use this setting when the dryer is mounted on the
same serial connected
Quadient
Base conveyor as
the print unit(s). The dryer will be turned off when a
stop of this conveyor is detected by the printer.
At
SET TIME[s]
you can set the duration (in seconds)
the dryer remains turned on after the last pages
exited the printer.
(0 – 60 sec. / Default: 5 seconds)
on 3rd party belt
Use this setting when the dryer is mounted on a third
party conveyor belt which is controlled independently
from the printer. At
SET TIME[s]
you can set the
duration (in seconds) the dryer remains turned on
after the last pages exited the printer.
(0 – 60 sec. / Default: 5 seconds)
Using a dryer!
Review all settings carefully before using a dryer!
Never operate a dryer without supervision of an operator!
divert
DISTANCE
Control option for a diverter placed behind the printer
(inline). The distance between paper sensor and
device has to be entered (range 0 – 5,000 mm). The
width (duration) of the signal pulse is calculated from
the transport speed and the material size in transport
direction. Any device in-between the printer and the
diverter can influence the distance.
divert
works for devices which are downstream from
the printer.
Trigger divert
The
divert
function must be
triggered from a PC application.
Default:
feeder control
Pos: 81.81 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1804_RELAY2 OUTPUT_AS-3060A, 620, Orbit, OrbitB @ 0\mod_1254913755613_912.doc @ 4855 @
Relay 2 OUTPUT
The functions of Relay 2 can be configured in the same way as
Relay 1 OUTPUT
. See above.
Default:
feeder control
Pos: 81.82 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1805_IN 1 INPUT @ 1\mod_1256285352045_912.doc @ 6991 @
IN 1 INPUT
Summary of Contents for AS-Orbit
Page 1: ...User guide AS Orbit Address Printer ...
Page 224: ...9204009J C 12 04 2021 ...