70
User Manual Version 3.1
Figure 30: Distances between TOF sensor (LS) and U1-U4
To check the accuracy of the
DIST. TOF-U1
setting, press Quick
+ Arrow up (Test
Print) while in the
DIST. TOF-U1
menu. The printer will now print a service test page (see
Figure 31). Measure the distance between the left edge of the media and the bar. It should
equal 10 mm. If not adjust the
DIST. TOF-U1
value.
Figure 31: DIST. TOF-U1 service test page
Pos: 81.26 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_1208_1210_DIST.U1-U2 / DIST.U2-U3 / DIST.U3-U4 @ 0\mod_1254749911701_912.doc @ 4237 @
DIST. U1-U2 / DIST. U2-U3 / DIST. U3-U4
Since the absolute position of the print units depends on the installation of the
Quadient
AS-Orbit, the distances between the print units can vary. Therefore the distances have
to be measured with an appropriate ruler or a measuring tape. Figure 32 shows the
required distances between the print units.