11.3.3
Changing the standard IP address of the device
If the fixed IP address of the HP-MSM-HB conflicts with another device bearing the same IP address on the
network, the fixed IP address of the HP-MSM-HB can be changed.
NOTICE
Device malfunction due to incorrect entries
While changing the IP address, it is possible that another EE cell might be overwritten by a
mistype, for example, and the HP-MSM-HB could thus be rendered unusable.
X
Only very skilled users should attempt to change the IP address.
You can change the preset IP address in the menu
Communication > Free communication
by means of
the following commands:
IP address
(Sample address)
192.
168.
116.
85
DHCP
Commands
se0328
xyz
se0329
xyz
se0330
xyz
se0331
xyz
se0332
001
Tab. 11.1: Changing the IP address
In this case
xyz
are place holders of the four IP-address bytes (values 1 - 254) which always have to be
entered with three digits!
For example, the number 84 has to be entered like this: 084.
For reasons of clarity the symbol
marks a space.
Example:
You want to change the IP address from 192.168.116.
85
to 192.168.116.
86
.
1. Please start the LaserDiagnosticsSoftware LDS (see chapter 12 on page 42).
2. Open the dialogue window
Communication > Free Communication
.
3. Choose in the field Mode
TCP
(the option “Second IP” must not be activated!).
4. Enter the current IP address in the
TCP
field.
5. Click on the
Connect
button (“connected” appears in the bus monitor).
6. Activate the check box
Write bus protocol
(the protocol can be helpful in case of problems):
• The protocol is saved in the installation directory of the LaserDiagnosticsSoftware LDS.
• The file name is buspro.log.YYYY/MM/DD (YYYY/MM/DD = date file was created).
7. Enter the following in the field
Command
:
se0331
086
(please make sure that the blank character
is entered correctly).
8. Click on the
Send
button and wait for the confirmation in the bus monitor
(see Fig. 11.4 on page 40 „-> Add:0331 value: 086“)
9. Please turn off the device and turn it on again:
• After the restart the IP-address is updated.