![Primes HP-MSM-HB Original Instructions Manual Download Page 40](http://html1.mh-extra.com/html/primes/hp-msm-hb/hp-msm-hb_original-instructions-manual_1601727040.webp)
40
Revision 00 EN - 01/2021
HP-MSM-HB
35,0(6
Confirmation
se0331 086
Adr: 0331 Wert:086
Fig. 11.4:
Changing the IP address in the dialogue window
Free Communication
11.3.4
Retrieve IP address automatically with DHCP
DHCP (Dynamic Host Configuration Protocol) enables the automatic integration of a device into an existing
network without its manual configuration.
You activate the DHCP function in the Laser Diagnostic Software with the command: se0331
001.
1. Please start the LaserDiagnosticsSoftware LDS (see chapter 12 on page 42).
2. Open the dialogue window
Communication > Free Communication
.
3. Choose in the field Mode
TCP
(the option “Second IP” must not be activated!).
4. Enter the current
IP address
in the
TCP
field.
5. Click on the
Connect
button (“connected” appears in the bus monitor).
6. Activate the check box
Write bus protocol
(the protocol can be helpful in case of problems):
• The protocol is saved in the installation directory of the LaserDiagnosticsSoftware LDS.
• The file name is buspro.log.YYYY/MM/DD (YYYY/MM/DD = date file was created).
7. Enter the following in the field
Command
:
se0331
001
(please make sure that the blank character
is entered correctly).
8. Click on the
Send
button and wait for the confirmation in the bus monitor
(see Fig. 11.5 on page 41 „-> Add:0331 value: 001“)
9. Please turn off the device and turn it on again.