D1-03: Absorption Voltage
Use this setting to specify the absorption voltage.
D1-04: Repeated Absorption Time
Use this setting to specify the duration of the repeated absorption “pulses”.
D1-05: Repeated Absorption Interval
Use this setting to specify the interval between repeated absorptions.
D1-06: Maximum Absorption Time
If the Charge Curve is fixed (D1-02=1), then this setting is used to determine the absorption
time.
In all other cases, this setting determines the maximum absorption time.
D1-07: Float Voltage
Use this setting to specify the float voltage.
D1-08: Charge Current
Use this setting to specify the current with which the battery is charged in the bulk phase.
※
Note: The actual charge current depends on other conditions also. Therefore, under certain
circumstances, it is possible that the actual charge current is lower than this setting. This can,
among others, be due to:
A low AC IN Current Limit (B2-05) in combination with a high load.
A high environmental temperature
A too high ripple voltage due to improper cabling.
D1-09: Stop After 10Hr Bulk
This is a safety setting. When the bulk phase lasts more than 10 hours, this can be indication
that a battery cell is damaged.
The absorption voltage (or the 14.4V for battery when Battery Safe (D1-02=3) mode is used)
will never be reached in that case and the other cells will be over-charged resulting in the
Summary of Contents for PM-1500SI-12X
Page 17: ...17 Battery Shore Power Max 5A Load ATS ON AC IN AC OUT 5A 2A 30A 5A B2 05 5A 3A ...
Page 31: ...31 3 4 Battery Connection 3 4 1 Star Connection Schematic ...
Page 32: ...32 3 4 2 Rail Connection Schematic ...
Page 37: ...36 4 1 The following is the structure of user constants ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...