8
(
1
)
X should be 1, output voltage = 90~120 VAC or 2, output voltage = 185~240 VAC
Output Voltage THD
<
5%
Power Factor (All Loads)
ˇ
No linger load, crest factor
3: 1
Cont. Power Output (W)
Under 70
℃
(cos
θ
=1.0)
1500W
(No derate)
3000W
(No derate)
Cont. Power Output (W)
Over 70
℃
(cos
θ
=1.0)
0W
(Shutdown)
0W
(Shutdown)
Maximum Power (W)
3000W
6000W
Maximum Efficiency (%)
82/84/85
84/86/89
Zero-load Power (W)
12W
18W
CHARGER
Input Voltage Range (VAC)
200~250 VAC / 100~125 VAC
Input Frequency
45-55Hz /55-65 Hz
Power Factor
1
Charge Characteristic
4-stage adaptive / Bulk-Absorption-Float-Equalize
Maximum DC Voltage Ripple (Vrms)
<
1.25 V
Charge Current House Battery (A)
70A/40A/20A
140A/70A/40A
Charge Current Starter Battery (A)
4A
Absorption Voltage Default (VDC)
14.4V / 28.8V / 57.6V
Float voltage Default (VDC)
13.8V / 27.6V / 55.2V
Equalize Voltage default (VDC)
13.2V / 26.4V / 52.8V
Output Charge Voltage (min ~ max)
8V~16V / 11V~32V / 22V~64V
Battery Temperature sensor
BTS-3
AC INPUT SWITCH
AC IN Terminal Circuit Breaker
15A (120V) /15A (230V)
30A (120V) /15A (220V)
Switch-over Time
a. inverter to AC input
0 msec.
b. AC input to inverter
0 msec.
Detection Time AC Input Fault
4 ~10 msec.
Trip Level AC Input to Inverter
90 VAC / 180 VAC
Trip Level Inverter to AC Input
94 VAC / 187 VAC
Min.~ Max. Frequency Range
45-55 Hz / 55-65 Hz
MECHANICAL
Cabinet / Protecting Class
Aluminum / IP20
Dimension (HXWXD)
362 x 258 x 370 mm
424 x 258 x 370 mm
Weight (kgs)
30 kgs
35 kgs
Summary of Contents for PM-1500SI-12X
Page 17: ...17 Battery Shore Power Max 5A Load ATS ON AC IN AC OUT 5A 2A 30A 5A B2 05 5A 3A ...
Page 31: ...31 3 4 Battery Connection 3 4 1 Star Connection Schematic ...
Page 32: ...32 3 4 2 Rail Connection Schematic ...
Page 37: ...36 4 1 The following is the structure of user constants ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...