73
D Group (AC CHARGER):
D1 Group (Charger)
D1-02: Charge Curve
Setting
Function
D1-02=1
Fixed
D1-02=2
Adaptive
D1-02=3
(Initial setting)
Ad Battery safe
The Fixed (D1-02=1) charge curve will have a fixed Absorption Time (D1-06).
The Adaptive (D1-02=2) and AdBattery safe (D1-02=3) curve derive the
Absorption time from the Bulk time. The maximum Absorption time of these charge curves
is determined by Absorption Time (D1-06) setting.
The Ad Battery safe (D1-02=3) curve has a special regulation in the absorption
phase. The absorption phase will start when the battery voltage reaches 14.4V( for 12V
batteries) regardless of the specified Absorption Voltage (D1-03). During the absorption
phase, the voltage will increase with a fixed ramp until the voltage reaches the absorption
voltage or the calculated absorption time is over in the latter case, the absorption phase will
end before the absorption voltage is reached.
64
60
56
52
48
44
40
20
22
24
26
28
30
32
1 hour Repeated Absorption
1 day
float
7 days
reduced
7 days reduced
float
A bsorption
Bulk hours
20 x B ulk-hours or
M ax.Absorption tim e
Battery Safe m ode
Tim e
Tim e
120%
100%
80%
60%
40%
20%
0%
16
15
14
13
12
11
10
A m ps
V olts
C harge voltage
C harge current
Summary of Contents for PM-1500SI-12X
Page 17: ...17 Battery Shore Power Max 5A Load ATS ON AC IN AC OUT 5A 2A 30A 5A B2 05 5A 3A ...
Page 31: ...31 3 4 Battery Connection 3 4 1 Star Connection Schematic ...
Page 32: ...32 3 4 2 Rail Connection Schematic ...
Page 37: ...36 4 1 The following is the structure of user constants ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...