21
MODE 3: Renewable Energy with Power Support
When Stackable Inverter enters to MODE 3, B2-09(AC IN DynaCur Limit)=0 (Disable) and
the value of B2-20 (MODE3: ACINCurrent Lmt) will be loaded to B2-05.
1. INVERTER Mode:
When the battery voltage is not lower than (B2-14) voltage value, inverter mode takes
priority to supply voltage to AC OUT for load consumption.
(INVERTER ON+ ATS OFF + AC CHARGER OFF)
Battery
Shore Power
Ready
Load
ATS OFF
AC IN
AC OUT
3A
5A
B2-05=5A
3A
45A
Solar
Charger
Solar Panel
or
2.
Power Control Mode
When AC IN power is ready, INVERTER is active and battery voltage is lower than
B2-14 voltage value and longer than the second time set in B2-15, ATS will be switched
on to ensure AC OUT to continuously supply the load. At the moment, AC OUT will be
supplied by AC IN power. At the same time, the battery is charged from AC IN power
(AC CHARGER OFF) only by other wind charger or DC generator charger.
The difference between MODE 3 and MODE 4 is that in MODE 3, when AC IN power
is ready, AC CHARGER is off and the battery is charged by other renewable energy.
This is why MODE 3 is called Green Power as Priority Support Mode
(INVERTER OFF+ ATS ON + AC CHARGER OFF)